Column Internals

Custom tower internals for optimal distribution and support

Lantec designs and manufactures the components that make packed towers work: liquid distributors for uniform flow, collector distributors for multi-section towers, multi-beam gas injected (MBGI) packing supports with near-100% open area, grid supports, and mist eliminators. Each component is engineered to minimize pressure drop while ensuring optimal performance.

Column Internals

Liquid Distributors

All Lantec liquid distributors are supported from a circumferential ring supplied as an integral part of the column. Distributors are furnished in sections suitable for installation through manway of specified dimension (normally 24"). Assembly hardware is included.

Pressure drop: Normally 0.25" WC or less.

Collector Distributors

Collector distributors are used when multiple packing sections are incorporated in the column design. Risers are generous in cross section and adequately covered, preventing water entrance and assuring free flow of air.

Pressure drop: 0.35" WC or less.

Multi Beam Gas Injected (MBGI) Packing Support

The MBGI packing support design offers almost 100% open area, minimizing pressure drop to the lowest practical level. MBGI construction allows installation through manway with manway size specified (normally 24"). All necessary assembly hardware including leveling clamps is provided.

Pressure drop: 0.1–0.15" WC.

Grid Supports

Grid support designs feature 75–80% open area. Design permits installation through manway, size to be specified by column designer (normally 24"). All necessary assembly hardware is included.

Pressure drop: Approximately 0.45" WC.

Mist Eliminators

Pad mist eliminators include support grids at top and bottom. Mist eliminator applications require special consideration to assure removal of entrained moisture in the effluent gas stream. Lantec provides application-specific recommendations based on gas velocity, droplet size distribution, and removal requirements.

Key Benefits

  • Industry-leading low pressure drop — MBGI supports at 0.1–0.15" WC; distributors at 0.25" WC or less
  • Custom engineering — Each component designed for specific application requirements
  • Manway installation — All components fit through standard 24" manway (or customer-specified size)
  • Complete hardware — Assembly hardware, leveling clamps, and gaskets included
  • Integral support ring — Distributors supported from circumferential ring supplied with column

Performance Data & Literature

Case Studies

Technical Specifications

Pressure Drop Summary

Component Typical Pressure Drop
Liquid Distributor ≤ 0.25" WC
Collector Distributor ≤ 0.35" WC
MBGI Packing Support 0.1–0.15" WC
Grid Support ~0.45" WC

Design Features

Component Open Area Installation Hardware
MBGI Support ~100% Through manway Leveling clamps included
Grid Support 75–80% Through manway Assembly hardware included
Liquid Distributor Through manway Assembly hardware included
Collector Distributor Through manway Assembly hardware included